Description
HOW IT WORKS
The water to be filtered flows through an inlet (1), welded tangential to the body, then moves downward towards the inner cone (2) as its speed increases. The centrifugal force created separates the heavier suspended solids from the water. The cleaned water hits the deflector (3) and goes back up through the outlet collector (4). Impurities are deposited below the deflector in the collection tank (5). The particles can either be discharged continuously or purged on a timed schedule via a drain hole (6).
FILTRATION EFFICIENCY
The cyclones product range features two series, the IC series with good separation performance and low head losses and the IC HF series, with excellent separation performance even up to 10 micron, but with high head loss. The diagram below shows the differences in separation efficiency between the IC and IC HF series.
REMOVAL EFFICIENCY
Comparison of IC and IC HF hydrocyclones
HEAD LOSS
STANDARD IC HYDROCYCLONE
Technical Specifications
MODEL | IC ¾” | IC 1” | IC 1”1/2 | IC 2” | IC 3” | IC DN100 | IC DN150 | IC DN200 | IC DN250 |
---|---|---|---|---|---|---|---|---|---|
Flow rate – m³/h – With ΔP from 0.2 to 1 bar | 3,5-7 | 6-12 | 11-25 | 18-40 | 32-56 | 52-102 | 91-194 | 186-468 | 295-725 |
Connections- In/Out | ¾”M | 1”M | 1”1/2M | 2”M | 3”M | DN100 | DN150 | DN200 | DN250 |
Connection Discharge | 3/8” F | ½” F | ½” F | ¾”F | ¾”F | 1”F | 1”1/2F | 1”1/2F | 2”F |
Maximum working pressure – Bar | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Max Temperature – °C | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 |
MODEL | IC ¾” | IC 1” | IC 1”1/2 | IC 2” | IC 3” | IC DN100 | IC DN150 | IC DN200 | IC DN250 |
Dimensions | |||||||||
A (mm) | 780 | 935 | 1050 | 1220 | 1550 | 2300 | 2700 | 3610 | 3610 |
B (mm) | 75 | 85 | 100 | 180 | 180 | 330 | 330 | 465 | 505 |
C (mm) | 80 | 100 | 130 | 180 | 355 | 355 | 345 | 525 | 589 |
D (mm) | 295 | 315 | 330 | 350 | 385 | 460 | 445 | 570 | 570 |
E (mm) | 295 | 315 | 330 | 350 | 385 | 460 | 460 | 890 | 990 |
F (mm) | 31 | 35 | 45 | 45 | 50 | 88 | 88 | 990 | 990 |
WEIGHT Kg | 11 | 15 | 21 | 32 | 51 | 73 | 118 | 187 | 278 |
HIGH EFFICIENCY IC HF HYDROCYCLONE
Technical Specifications
MODEL | IC HF ¾” | IC HF 1” | IC HF 1”1/2 | IC HF 2” | IC HF 3” | IC HF DN100 | IC HF DN150 |
---|---|---|---|---|---|---|---|
Flow rate – m³/h – With ΔP from 0.2 to 1 bar | 2-6 | 4-8 | 8-16 | 18-40 | 28-38 | 40-68 | 91-194 |
Connections- In/Out | ¾”M | 1”M | 1”1/2M | 2”M | 3”M | DN100 | DN150 |
Connection Discharge | 3/8” F | ½” F | ½” F | ¾”F | ¾”F | 1”F | 1”1/2F |
Maximum working pressure – Bar | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Max Temperature – °C | 60 | 60 | 60 | 60 | 60 | 60 | 60 |
MODEL | IC HF ¾” | IC HF 1” | IC HF 1”1/2 | IC HF 2” | IC HF 3” | IC HF DN100 | IC HF DN150 |
Dimensions | |||||||
A (mm) | 780 | 935 | 1050 | 1220 | 1555 | 2300 | 2700 |
B (mm) | 75 | 85 | 110 | 140 | 140 | 255 | 330 |
C (mm) | 80 | 100 | 130 | 180 | 355 | 355 | 345 |
D (mm) | 295 | 315 | 330 | 350 | 385 | 460 | 445 |
E (mm) | 295 | 315 | 330 | 350 | 385 | 460 | 590 |
F (mm) | 31 | 43 | 45 | 46 | 54 | 105 | 600 |
WEIGHT Kg | 11 | 15 | 21 | 32 | 51 | 73 | 118 |