SCR LM & OM HT

SUCTION SCANNER SELF CLEANING FILTER MICROFILTRATION HIGH TEMPERATURE ASI316 (MEDIUM FLOW RATE)

MAX TEMPERATURE 85°

FILTER EFFICIENCY >98%

MAIN TECHNICAL FEATURES:

APPLICATIONS

HOW IT WORKS

The water enters the filter at (IN) inlet point and runs through the filtering cylinder (1) in outward direction. Thus, all suspended non-deformable solid particles larger or equal to the filtration degree set are retained. The filtered water flows out through the outlet (OUT) pipe.

REGENERATION

Constant deposit of suspended solid particles inside the filtering cylinder (1) obstructs the passage of water, causing a pressure differential (∆P). At a preset ∆P value (ranging from 0.3 ÷ 1 Bar) an automatic cleaning cycle of the filtering (1) cylinder starts. This activity begins with a signal that opens the discharge valve (2) allowing communication of the suction nozzles (3) with the outside environment. At the same time, the electric motor’s (4) rotary motion allows the nozzles to inspect the entire filtering surface. Dirt is removed through the discharge valve (2). The cleaning cycle lasts 15 sec.

CONTROL

A switchboard controls the washing phases. The signal that starts the cleaning cycle is given by a differential pressure switch. The switchboard gives an “alarm” signal in case of problems in the washing system. These signals can be sent to a pre-existing control centre. The washing phase can also be controlled manually. The solenoid controlling the valve is pneumatic.

DIMENSIONS AND TECHNICAL DATA

VERTICAL MODEL (SCR L M)

HORIZONTAL MODEL (SCR L OM)

DATA TABLE

PART DESCRIPTION

FLOW RATE

DO YOU NEED HELP?

CONTACT FORM

 

Submit

CONTACT

HOURS